Sample data/Demo reference

The knowledge base ships with two pieces of HVAC equipment, a fault-code reference, a parts catalog, and maintenance procedures. Use the codes below to get reproducible answers and to drive the voice demo. You can extend any of it on the Knowledge page.

AHU-12 · Air Handling Unit
Carrier 39M · roof-mounted · Plant Room B · serves floors 3 to 5
  • Supply airflow: 8,000 CFM nominal
  • Supply fan motor: 7.5 kW, 400 V three-phase, belt driven
  • Filter bank: MERV 13, replaced every 90 days
  • Fan bearing housing bolts: 30 newton metres
  • Supply air temperature: 13 to 15 °C in cooling
CH-02 · Water-Cooled Chiller
York YK · single-stage centrifugal · basement plant · lead chiller
  • Cooling capacity: 500 tons nominal
  • Refrigerant: R-134a, charge 180 kg
  • Oil pressure: 200 to 250 kilopascals
  • Chilled water supply: 6 to 7 °C
  • High condenser pressure trip: 1,200 kPa
Fault codes
Spoken codes the assistant recognises
  • F-301Low oil pressure — stop the compressor and inspect the oil systemcritical
  • F-203Low refrigerant pressure — isolate, leak test, check chargehigh
  • F-117High condenser pressure — verify water flow, clean tubesmedium
  • F-088Supply fan belt slip — re-tension or replace the beltlow
  • F-145Dirty filter — replace the panel filterslow
Parts catalog
  • P/N 88-22ASupply fan belt for AHU-12
  • P/N 45-90CMERV 13 panel filter, pack of four, AHU-12
  • P/N 12-77ROil filter element for CH-02 compressor
  • P/N 33-50VChilled water expansion valve, AHU-12 coil
  • P/N 70-10GR-134a refrigerant cylinder, 12 kilograms
Try these out loud
One script per capability
  • Inspection“CH-02 oil pressure dropped to 130 kilopascals, fault F-301, this is critical, I stopped the compressor.”
  • Question“What is the torque spec for the AHU-12 fan bearing housing bolts?”
  • Command“Create a work order for CH-02, fault F-301, low oil pressure, critical.”